X79-DELUXE motherboard adopts the current mainstream technology design, which is suitable for high-end players in the game, and has been loved by many people. Now I will teach you how to repair the X79-DELUXE motherboard.
Tools/Materials
1

X79-DELUXE motherboard

2

A universal electric meter

Methods/Steps
1

From the perspective of the motherboard framework, it uses the INTEL LGA2011 PROCESSOR, which is one of the mainstream architectures at present and is suitable for most high-end gamers. It uses the LGA2011 CPU type, supports DDR3 CHA/CHB/CHC/CHD four-channel memory, plus dual unique interface, supports PCI-E X16/X8/X4 expansion function, and peripheral devices are mainly controlled by PCH chip, external expansion function is more powerful than LGA1150 series.

2

From the voltage distribution point of view, the voltage stability and the overall efficiency of the main board are improved. Main voltage ATX12V_1/ATX12V_2, +5V, +5VSB_ATX, +3.3V The voltage is output by the ATXPWR power supply interface, and then sent to each module on the mainboard after a series of converters, including +1.5V_DUAL, VTT_DDR for memory power supply. And the CPU power supply VCORE(0.85V~1.7V), +VSA_CPU(0.85V~1.7V), +VTTCPU(1.05V/1.1V), etc.

3

The whole boot process of the motherboard, a total of 21 steps, cumbersome replacement. From POWEER ON to the generation of PLTRST#, encounter the motherboard NO BOOT, to check from the last stage forward direction, for example, found that PLTRST# signal no output, you should check whether the former signal VSA has a problem, to go forward to find a solution to troubleshoot the fault.

4

The overall frequency layout of the motherboard is more systematic, mainly provided to each module by CLOCK CHIP-CLOCK Buffe-PCH after BUFFE. When measuring, the HZ gear of the multimeter should be used to check whether the frequency value is normal

5

During maintenance, the position and measurement method of each voltage point: The multimeter gear measures the bipolar value of each voltage point to the ground. The red number in the figure is the normal bipolar value, for example: PU400 +VCCPLL 471,471 represents the bipolar value, PU400 represents the position of the part, and +VCCPLL represents the signal name; A small bipolar value indicates a short circuit, and a large value indicates an open circuit.

6

Position and measurement of important signal points of the main board. Multimeter measurement method refer to the measurement method in step 5; After completing the above six steps, I believe that the fault of the motherboard can also be found and solved.